IMPORTANT INSTALLATION CONSIDERATIONS:

 

ICMG 1201 (Color:  Black) 1/2" fpt x 1/2" fpt

ICMG 1201-Low (Color: Gray) 1/2" fpt x 1/2" fpt for use on a dedicated low pH (acid) line
(Not for Use with HF or ABF)

ICMG 3401 (Color: Black) 3/4" fpt x 3/4" fpt 

 

  1. CAUTION: DO NOT OVERTIGHTEN! Use at least 5 tight wraps of teflon tape on male pipe threads and teflon-based paste on top of tape to ensure positive thread sealing.

  2. Carefully observe flow direction arrow for proper orientation.

  3. Use care when tightening fittings.

  4. Do not use the iCheck MagnumTM in systems where temperatures above 180 degF may exist! Observe max pressure rating on valve body!